BLWMR - WILHOLD CONCRETE ADHESIVE

  • MSDS: BLWMR
  • Manufacturer: DAP INC
  • Product Name: WILHOLD CONCRETE ADHESIVE
  • National Stock Number: 8040-00N017701
Product Identification

Product ID:WILHOLD CONCRETE ADHESIVE
MSDS Date:11/23/1987
FSC:8040
NIIN:00N017701
MSDS Number: BLWMR

Responsible Party
DAP INC
DAYTON, OH 45401
US

Emergency Phone: 513-263-7164

Info Phone: 513-263-7164

Preparer: A M GASSNER

Cage: 90300

Contractor
DAP INC.
277 DAYTON, OH 45401-0277 US

Telephone: 513-253-7154/800-543-3840

Cage: 90300

Ingredients

ETHANE,1,1,1-TRICHLORO-;(1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: <2%

OSHA PEL 350PPM; 450PPM, STEL

ACGIH TLV: 350PPM; 450PPM, STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETIC ACID, VINYL ESTER;(VINYL ACETATE POLYMER)

CAS: 108-05-4

RTECS: AK0875000

Fraction By Weight: 30-45%

OSHA PEL 10 PPM/15 STEL

ACGIH TLV: 10 PPM/15,A3 STEL;93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 25-40%

Hazards

LD50 LC50 Mixture:LD50: ORAL(RAT) >10G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES/SKIN: VAPOR MAY CAUSE
IRRIT. INHAL: VAPOR MAY AFFECT BRAIN/NERVOUS SYSTEM CAUSING
HDACH/DIZZ/NAUS. INGEST: CAUSES NAUS/VOMIT/DIARR. CHRONIC: RPTD
EXPOS TO SKIN MAY RESULT IN DERMATITIS. RE PORTS HAVE ASSOCIATED
RPTD/PRLNG OCCUPATIONAL OVEREXP TO SOLVENTS W/PERMANENT BRAIN &
NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PRE-EXISTING SKIN DISORDERS,
IMPAIRED PULMONARY FUNCTIONS, LIVER AND KIDNEY DISORDERS AND
CARDIOVASCULAR CONDITIONS.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR; RESTORE BRTHG IF NECESSARY.
CONTACT MD. EYES: FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15
MIN. CONTACT MD IMMED. SKIN: WASH W/SOAP & WATER. CONSULT MD IF
IRRITATION DEVE LOPS. INGEST: DO NOT INDUCE VOMITING. IF VICTIM IS
CONSCIOUS, GIVE WATER OR MILK. CONTACT MD IMMMED.

Fire Fighting

Flash Point Method:CC
Flash Point:NONE
Extinguishing Media:FOAM, WATER FOG, DRY CHEMICALS, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT TO PROTECT FROM COMBUSTION PRODUCTS.
COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL &/OR PHOSGENE .

Accidental Release

Spill Release Procedures:SMALL SPILL: USE ABSORBENT MATL OR SCRAPE UP
DRIED MATL & PLACE INTO CONTRS. LARGE SPILL: WEAR PROT EQUIP &
PROVIDE ADEQ VENT. CONTAIN SPILL BY DIKING TO PVNT SPREADING.
ABSORB SPILL W/SAND, EARTH, OI L DRY OR OTHER ABSORBENT MATL &
SHOVEL (SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTRS FROM EXCESSIVE HEAT/FRZ.
KEEP CONTRS TIGHTLY CLOSED WHEN NOT IN USE. KEEP OUT OF REACH OF
CHILDREN. STORE AWAY FROM OXIDIZERS/CAUSTICS.
Other Precautions:USE ONLY W/ADEQ VENT & ELIM SOURCES OF IGNIT WHEN
PROD IS USED. AVOID PRLNG/RPTD BRTHG OF SOLV VAPS & CONT W/PROD. NO
SMKG IN AREA OF USE. DO NOT USE IN THE GEN VICIN OF ARC
WELDING/OPEN FLAMES/HOT SU RFACES. HEAT &/OR UV RADIA (SUPP DATA)

Exposure Controls

Respiratory Protection:IF 8-HR EXPOSURE LIMIT OR VALUE IS EXCEEDED FOR
ANY COMPONENT, USE AN APPROVED NIOSH/MSHA RESPIRATOR. CONSULT YOUR
SAFETY EQUIPMENT SUPPLIER AND THE OSHA REGULATION, 29CFR 1910.134
FOR RESPIRATOR REQU IREMENTS.
Ventilation:PROVIDE SUFFICIENT MECH VENT (LOC/GEN EXHAUST) TO MAINTAIN
ADEQ AIR MOVEMENT TO KEEP EXPOSURE BELOW PEL/TLV. (SUPP DATA)
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROVIDE EYEWASH & SOLVENT IMPERVIOUS APRON
IF BODY CONTACT WITH PRODUCT MAY OCCUR. BARRIER CREAMS MAY BE USED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC: INTO CONTRS. PREVENT RUN-OFF TO SEWERS/STREAMS/LAKES OR
OTHER BODIES OF WATER; NOTIFY LOC HLTH & WILDLIFE OFFICIALS IF
RUN-OFF OCCURS. OTHER PREC: MAY CAUSE THE FORMATION OF HCL &/OR
PHOSG ENE . VENT: VAPORS ARE HEAVIER THAN AIR & WILL COLLECT IN LOW
AREAS.

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:24 @ 25C
Vapor Density:0.6
Spec Gravity:1.09
Evaporation Rate & Reference:NOT AVAILABLE
Solubility in Water:LIMITED
Appearance and Odor:WHITE PASTE WITH SWEETISH ODOR.
Percent Volatiles by Volume:52-56

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, CAUSTIC ALKALI.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:NORMAL COMBUSTION PRODUCTS, I.E. CO*X,
CL*X, HCL, PHOSGENE .

Disposal

Waste Disposal Methods:DISCARDED SPILL RESIDUE MAY BE INCINERATED. DO
NOT INCINERATE SEALED CONTRS. DISPOSE ACCORDING TO FEDERAL, STATE &
LOCAL REGULATIONS. LIQUIDS CANNOT BE DISPOSED OF IN A LANDFILL. DO
NOT REUSE EMPTY CO NTRS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.